XP110 1/4″ Adjustable Pressure Switch for Boiler Steam Iron
₹1,200.00 मूल कीमत थी: ₹1,200.00.₹799.00वर्तमान कीमत है: ₹799.00.
उत्पाद वर्णन
XP110 Miniature 1/4″ Adjustable Pressure Switch
The XP110 Miniature 1/4″ Adjustable Pressure Switch is a compact mechanical pressure-control component designed for compatible industrial steam iron boilers, steam generators and commercial garment pressing equipment.
The switch monitors steam pressure inside the boiler and operates its electrical contacts when the pressure reaches the configured switching point. This allows the connected boiler control circuit to switch the heating system ON/OFF according to the pressure setting, helping maintain consistent steam pressure during operation.
With a compact body, adjustable pressure setting and 1/4″ threaded connection, the XP110 is suitable for compatible boiler control compartments where space is limited.
It can be used in compatible industrial steam boiler systems associated with Magneto, Silver Star, Hashima, Veit, Naomoto and Silter, including compatible 3L/5L commercial steam boilers, subject to matching pressure range, thread type, electrical rating and mounting configuration.
WHAT YOU GET
- 1 × XP110 Miniature Pressure Switch
- 1/4″ threaded pressure connection
- Adjustable pressure-control mechanism
- Electrical switching contacts
KEY FEATURES
Adjustable Steam Pressure Control
The XP110 features an adjustable pressure-setting mechanism that allows the switching threshold to be set according to the requirements of a compatible steam boiler control system.
This helps maintain more consistent boiler pressure during garment pressing and steam-ironing operations.
Automatic Heating Control
When correctly integrated into the boiler’s control circuit, the pressure switch can control the heating element or contactor according to the detected boiler pressure.
Typical operation:
Pressure Low → Heating ON
Target Pressure Reached → Heating OFF
The exact switching behaviour depends on the boiler’s electrical control circuit and the pressure-switch configuration.
1/4″ Threaded Connection
The XP110 uses a 1/4″ male threaded pressure connection for installation into a compatible boiler pressure port.
महत्वपूर्ण: 1/4″ BSP and 1/4″ NPT are different thread standards. Do not force a mismatched thread. Verify the actual thread type of your existing switch and boiler connection before installation.
Compact Miniature Design
The small housing is suitable for boiler control compartments where installation space is restricted.
Brass & Heat-Resistant Construction
The pressure connection uses a durable metal construction designed for demanding steam-boiler environments.
The pressure-sensing mechanism is designed to operate under compatible temperature and pressure conditions.
Electrical Switching Contacts
The internal microswitch provides electrical switching for a compatible boiler control circuit.
For higher-power heating elements, the pressure switch should be used with an appropriately rated contactor or relay where required.
Pressure Safety Control
When correctly selected, adjusted and installed, the pressure switch can help prevent continued heating after the configured pressure threshold is reached.
It should not be considered a substitute for an independent boiler safety valve, pressure relief device or other mandatory safety protection.
COMPATIBLE BOILER STEAM IRON BRANDS
The XP110 can be suitable for compatible industrial steam boiler systems from:
Magneto Steam Boilers
Suitable for compatible Magneto industrial steam boiler and garment pressing systems using the corresponding pressure-switch configuration.
Silver Star Steam Boilers
Suitable for compatible Silver Star steam boiler and industrial ironing equipment where pressure range, thread and electrical specifications match.
Hashima Steam Systems
Suitable for compatible Hashima industrial steam boilers using the corresponding pressure-control arrangement.
Veit Steam Equipment
Suitable for compatible Veit garment pressing and steam boiler systems where the original pressure switch matches the XP110 specifications.
Naomoto Steam Boilers
Suitable for compatible Naomoto industrial steam boiler systems with matching pressure-control requirements.
Silter Steam Boilers
Suitable for compatible Silter steam boiler and ironing equipment where the existing pressure switch specifications match.
3L / 5L Commercial Steam Boilers
Suitable for compatible 3L and 5L industrial/commercial steam boilers, provided the original pressure switch has matching:
- Pressure range
- Thread specification
- Electrical rating
- Switching configuration
- Physical dimensions
Boiler capacity alone does not confirm compatibility.
THREAD COMPATIBILITY
The product is specified with a 1/4″ threaded pressure connection.
Before ordering, confirm whether your boiler uses:
- 1/4″ BSP
- 1/4″ NPT
- Another 1/4″ thread standard
1/4″ BSP and 1/4″ NPT should not be treated as interchangeable threads.
If the thread type is uncertain, compare the original pressure switch or consult the boiler manufacturer/technician.
COMMON APPLICATIONS
The XP110 pressure switch can be used in compatible:
- Industrial steam irons
- Steam boiler machines
- Steam generators
- Garment pressing machines
- Commercial steam ironing systems
- Laundry pressing equipment
- Textile finishing machinery
- Industrial garment finishing equipment
- Boiler heating-control panels
- Steam generator control systems
TYPICAL PRESSURE-CONTROL OPERATION
Step 1 – Boiler Pressure Builds
The boiler heating element raises the temperature and steam pressure.
Step 2 – Pressure Is Detected
The XP110’s pressure-sensing mechanism responds to the increasing boiler pressure.
Step 3 – Set Pressure Is Reached
When the configured switching threshold is reached, the electrical contacts change state.
Step 4 – Heating Control Changes
The connected control circuit can switch the heating element or contactor OFF.
Step 5 – Pressure Falls
As steam is consumed during ironing, boiler pressure decreases.
Step 6 – Heating Restarts
When the pressure reaches the configured restart threshold, the control circuit can switch heating back ON.
The actual cut-in/cut-out behaviour depends on the pressure-switch adjustment, differential and boiler control circuit.
IMPORTANT: PRESSURE SETTING
Pressure adjustment should not be performed by guesswork.
The correct pressure setting must be based on:
- Boiler manufacturer’s specification
- Safe operating pressure
- Heating system requirements
- Pressure gauge reading
- Safety-valve setting
- Pressure-switch range
- Machine operating instructions
Do not set the pressure switch above the boiler’s permitted operating pressure.
PRODUCT SPECIFICATIONS
| विनिर्देश | विवरण |
|---|---|
| उत्पाद का प्रकार | Miniature Adjustable Pressure Switch |
| नमूना | XP110 |
| आवेदन | Industrial Steam Boiler |
| Connection | 1/4″ Male Thread* |
| Thread Standard | BSP / NPT Variant* |
| समारोह | Steam Pressure Control |
| Switching Type | Mechanical Microswitch |
| Pressure Setting | Adjustable* |
| Installation | Boiler Pressure Port |
| पैक मात्रा | 1 टुकड़ा |
| कपड़े का प्रकार | N/A |
*Verify the exact thread standard, pressure range and electrical rating of the supplied variant before installation.
WHY REPLACE THE BOILER PRESSURE SWITCH?
A faulty or worn pressure switch may result in:
- Boiler heating not switching correctly
- Heating staying ON continuously
- Heating switching OFF too early
- Unstable steam pressure
- Incorrect pressure cycling
- Intermittent electrical contacts
- Boiler control faults
Replacing the pressure switch with a correctly specified unit can restore pressure-based heating control.
COMPATIBILITY CHECKLIST
Before ordering, compare your existing pressure switch for:
- XP110 model/configuration
- 1/4″ thread size
- BSP or NPT thread standard
- Pressure range
- Cut-in pressure
- Cut-out pressure
- Electrical contact rating
- Number of electrical terminals
- Mounting orientation
- Physical dimensions
- Pressure-port configuration
Do not purchase based on model name alone. Matching the pressure range, thread and electrical specifications is essential.
INSTALLATION
The XP110 is used in pressurized steam boiler systems and electrical heating circuits. Installation and adjustment should be performed by a qualified boiler/electrical technician.
General replacement procedure:
- Switch OFF the boiler’s electrical supply.
- Allow the boiler to cool completely.
- Release pressure according to the boiler manufacturer’s procedure.
- Confirm that the boiler is fully depressurized.
- Disconnect the existing pressure switch wiring.
- Record the original terminal connections.
- Remove the existing pressure switch.
- Verify the replacement thread matches the boiler port.
- Install the XP110 using an appropriate compatible sealing method.
- Connect the electrical wiring according to the original boiler circuit.
- Check for steam/water leakage.
- Verify the pressure gauge and safety devices.
- Test the pressure-switch operation at a safe pressure.
- Confirm that the heating system cycles correctly.
Never work on a hot or pressurized boiler.
SAFETY INFORMATION
This product is used with pressurized steam, high temperatures and potentially hazardous electrical loads.
For safe operation:
- Never open or remove the pressure switch from a pressurized boiler.
- Allow the boiler to cool before servicing.
- Disconnect mains power before electrical work.
- Never bypass the pressure switch.
- Never bypass the boiler safety valve.
- Never operate without the required pressure-relief devices.
- Do not exceed the boiler’s rated working pressure.
- Do not exceed the pressure switch’s specified electrical rating.
- Use a suitable relay/contactor for high-power heating loads where required.
- Verify the pressure gauge before adjusting the switch.
- Installation should be performed by a qualified technician.
FREQUENTLY ASKED QUESTIONS
What is an XP110 pressure switch?
The XP110 is a miniature adjustable mechanical pressure switch used to monitor pressure and control an electrical circuit in compatible steam boilers and other pressure-control applications.
What is the main function of this switch?
Its primary function is to switch an electrical circuit according to a preset pressure condition.
Can it control a boiler heating element?
Yes, when correctly selected and installed in a compatible boiler control circuit. For high-power heating elements, a contactor or relay may be required.
What thread does the XP110 use?
This product is specified with a 1/4″ male threaded connection. Verify whether your required version is BSP or NPT before ordering.
Are 1/4″ BSP and 1/4″ NPT the same?
No. They are different thread standards and should not be treated as interchangeable.
Can I use it on a 3L steam boiler?
It can be used on a compatible 3L boiler if the pressure range, thread, electrical rating and switching configuration match.
Can it be used on a 5L steam boiler?
Yes, it can be suitable for a compatible 5L industrial steam boiler when all specifications match.
Is it compatible with Magneto steam boilers?
It can be used with compatible बिजली की शक्ति उत्पन्न करने का यंत्र boiler systems where the original pressure switch matches the XP110 specifications.
Does it fit Silver Star boilers?
It is suitable for compatible Silver Star systems when the pressure range, thread and electrical specifications match.
Can it be used with Hashima boilers?
Yes, it can be suitable for compatible Hashima steam boiler systems with matching specifications.
Is it compatible with Veit boilers?
It can be used in compatible Veit steam equipment where the original pressure switch specifications match.
Can it be used with Naomoto boilers?
Yes, it can be suitable for compatible Naomoto industrial steam boiler systems when the specifications match.
Is it suitable for Silter boilers?
It can be used with compatible Silter steam boiler systems with matching pressure-switch specifications.
Is the pressure adjustable?
Yes. The XP110 design includes an adjustable pressure-setting mechanism. The setting must be adjusted according to the boiler manufacturer’s safe operating specifications.
Does the pressure switch replace the boiler safety valve?
नहीं।. A pressure switch is a control device and should not be treated as a replacement for a safety/pressure-relief valve.
Can I adjust the pressure myself?
Pressure adjustment should be performed by a qualified technician using the boiler’s pressure gauge and manufacturer’s specifications.
How do I know if this pressure switch will fit?
तुलना करना:
- Thread size
- BSP/NPT standard
- Pressure range
- Electrical rating
- Terminal configuration
- Physical dimensions
- Original model/configuration