{"id":20749,"date":"2026-08-25T18:10:39","date_gmt":"2026-08-25T12:40:39","guid":{"rendered":"https:\/\/stitchpartner.com\/?post_type=product&#038;p=20749"},"modified":"2026-08-29T22:56:36","modified_gmt":"2026-08-29T17:26:36","slug":"xp110-1-4-adjustable-pressure-switch-boiler-steam-iron","status":"publish","type":"product","link":"https:\/\/stitchpartner.com\/hi\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/","title":{"rendered":"XP110 1\/4&#8243; Adjustable Pressure Switch for Boiler Steam Iron"},"content":{"rendered":"<h1 data-start=\"106\" data-end=\"331\"><strong data-start=\"110\" data-end=\"161\">XP110 Miniature 1\/4&#8243; Adjustable Pressure Switch<\/strong><\/h1>\n<p class=\"PDq2pG_selectionAnchorContainer\" data-start=\"106\" data-end=\"331\">The <strong data-start=\"110\" data-end=\"161\">XP110 Miniature 1\/4&#8243; Adjustable Pressure Switch<\/strong> is a compact mechanical pressure-control component designed for compatible <strong data-start=\"237\" data-end=\"330\">industrial steam iron boilers, steam generators and commercial garment pressing equipment<\/strong>.<\/p>\n<p data-start=\"333\" data-end=\"665\">The switch monitors steam pressure inside the boiler and operates its electrical contacts when the pressure reaches the configured switching point. This allows the connected boiler control circuit to <strong data-start=\"533\" data-end=\"603\">switch the heating system ON\/OFF according to the pressure setting<\/strong>, helping maintain consistent steam pressure during operation.<\/p>\n<p data-start=\"667\" data-end=\"838\">With a compact body, adjustable pressure setting and <strong data-start=\"720\" data-end=\"748\">1\/4&#8243; threaded connection<\/strong>, the XP110 is suitable for compatible boiler control compartments where space is limited.<\/p>\n<p data-start=\"840\" data-end=\"1129\">It can be used in compatible industrial steam boiler systems associated with <strong data-start=\"917\" data-end=\"976\">Magneto, Silver Star, Hashima, Veit, Naomoto and Silter<\/strong>, including compatible <strong data-start=\"999\" data-end=\"1033\">3L\/5L commercial steam boilers<\/strong>, subject to matching pressure range, thread type, electrical rating and mounting configuration.<\/p>\n<h2 data-section-id=\"1rbzvcq\" data-start=\"1131\" data-end=\"1146\">WHAT YOU GET<\/h2>\n<ul data-start=\"1148\" data-end=\"1297\">\n<li data-section-id=\"9b39bp\" data-start=\"1148\" data-end=\"1189\"><strong data-start=\"1150\" data-end=\"1189\">1 \u00d7 XP110 Miniature Pressure Switch<\/strong><\/li>\n<li data-section-id=\"1it101o\" data-start=\"1190\" data-end=\"1225\">1\/4&#8243; threaded pressure connection<\/li>\n<li data-section-id=\"4qqa8b\" data-start=\"1226\" data-end=\"1265\">Adjustable pressure-control mechanism<\/li>\n<li data-section-id=\"50uouf\" data-start=\"1266\" data-end=\"1297\">Electrical switching contacts<\/li>\n<\/ul>\n<h1 data-section-id=\"1ukjtrq\" data-start=\"1299\" data-end=\"1313\">KEY FEATURES<\/h1>\n<h3 data-section-id=\"fho0gt\" data-start=\"1315\" data-end=\"1352\">Adjustable Steam Pressure Control<\/h3>\n<p data-start=\"1354\" data-end=\"1534\">The XP110 features an adjustable pressure-setting mechanism that allows the switching threshold to be set according to the requirements of a compatible steam boiler control system.<\/p>\n<p data-start=\"1536\" data-end=\"1641\">This helps maintain more consistent boiler pressure during garment pressing and steam-ironing operations.<\/p>\n<h3 data-section-id=\"5su1lw\" data-start=\"1643\" data-end=\"1672\">Automatic Heating Control<\/h3>\n<p data-start=\"1674\" data-end=\"1842\">When correctly integrated into the boiler&#8217;s control circuit, the pressure switch can control the heating element or contactor according to the detected boiler pressure.<\/p>\n<p data-start=\"1844\" data-end=\"1862\">Typical operation:<\/p>\n<p data-start=\"1864\" data-end=\"1893\"><strong data-start=\"1864\" data-end=\"1893\">Pressure Low \u2192 Heating ON<\/strong><\/p>\n<p data-start=\"1895\" data-end=\"1936\"><strong data-start=\"1895\" data-end=\"1936\">Target Pressure Reached \u2192 Heating OFF<\/strong><\/p>\n<p data-start=\"1938\" data-end=\"2057\">The exact switching behaviour depends on the boiler&#8217;s electrical control circuit and the pressure-switch configuration.<\/p>\n<h3 data-section-id=\"16u2jjr\" data-start=\"2059\" data-end=\"2087\">1\/4&#8243; Threaded Connection<\/h3>\n<p data-start=\"2089\" data-end=\"2205\">The XP110 uses a <strong data-start=\"2106\" data-end=\"2148\">1\/4&#8243; male threaded pressure connection<\/strong> for installation into a compatible boiler pressure port.<\/p>\n<p data-start=\"2207\" data-end=\"2406\"><strong data-start=\"2207\" data-end=\"2221\">\u092e\u0939\u0924\u094d\u0935\u092a\u0942\u0930\u094d\u0923:<\/strong> 1\/4&#8243; BSP and 1\/4&#8243; NPT are different thread standards. Do not force a mismatched thread. Verify the actual thread type of your existing switch and boiler connection before installation.<\/p>\n<h3 data-section-id=\"e0h287\" data-start=\"2408\" data-end=\"2436\">Compact Miniature Design<\/h3>\n<p data-start=\"2438\" data-end=\"2539\">The small housing is suitable for boiler control compartments where installation space is restricted.<\/p>\n<h3 data-section-id=\"e0ux2g\" data-start=\"2541\" data-end=\"2580\">Brass &amp; Heat-Resistant Construction<\/h3>\n<p data-start=\"2582\" data-end=\"2689\">The pressure connection uses a durable metal construction designed for demanding steam-boiler environments.<\/p>\n<p data-start=\"2691\" data-end=\"2798\">The pressure-sensing mechanism is designed to operate under compatible temperature and pressure conditions.<\/p>\n<h3 data-section-id=\"1em4f3d\" data-start=\"2800\" data-end=\"2833\">Electrical Switching Contacts<\/h3>\n<p data-start=\"2835\" data-end=\"2930\">The internal microswitch provides electrical switching for a compatible boiler control circuit.<\/p>\n<p data-start=\"2932\" data-end=\"3068\">For higher-power heating elements, the pressure switch should be used with an appropriately rated <strong data-start=\"3030\" data-end=\"3052\">contactor or relay<\/strong> where required.<\/p>\n<h3 data-section-id=\"17n8ahk\" data-start=\"3070\" data-end=\"3097\">Pressure Safety Control<\/h3>\n<p data-start=\"3099\" data-end=\"3254\">When correctly selected, adjusted and installed, the pressure switch can help prevent continued heating after the configured pressure threshold is reached.<\/p>\n<p data-start=\"3256\" data-end=\"3401\"><strong data-start=\"3256\" data-end=\"3401\">It should not be considered a substitute for an independent boiler safety valve, pressure relief device or other mandatory safety protection.<\/strong><\/p>\n<h1 data-section-id=\"wxm1ib\" data-start=\"3403\" data-end=\"3440\">COMPATIBLE BOILER STEAM IRON BRANDS<\/h1>\n<p data-start=\"3442\" data-end=\"3520\">The XP110 can be suitable for compatible industrial steam boiler systems from:<\/p>\n<h2 data-section-id=\"13ohc58\" data-start=\"3522\" data-end=\"3546\">Magneto Steam Boilers<\/h2>\n<p data-start=\"3548\" data-end=\"3687\">Suitable for compatible Magneto industrial steam boiler and garment pressing systems using the corresponding pressure-switch configuration.<\/p>\n<h2 data-section-id=\"1g4j550\" data-start=\"3689\" data-end=\"3717\">Silver Star Steam Boilers<\/h2>\n<p data-start=\"3719\" data-end=\"3866\">Suitable for compatible Silver Star steam boiler and industrial ironing equipment where pressure range, thread and electrical specifications match.<\/p>\n<h2 data-section-id=\"qjyi3u\" data-start=\"3868\" data-end=\"3892\">Hashima Steam Systems<\/h2>\n<p data-start=\"3894\" data-end=\"4004\">Suitable for compatible Hashima industrial steam boilers using the corresponding pressure-control arrangement.<\/p>\n<h2 data-section-id=\"1m6sgz3\" data-start=\"4006\" data-end=\"4029\">Veit Steam Equipment<\/h2>\n<p data-start=\"4031\" data-end=\"4170\">Suitable for compatible Veit garment pressing and steam boiler systems where the original pressure switch matches the XP110 specifications.<\/p>\n<h2 data-section-id=\"3ebq3i\" data-start=\"4172\" data-end=\"4196\">Naomoto Steam Boilers<\/h2>\n<p data-start=\"4198\" data-end=\"4306\">Suitable for compatible Naomoto industrial steam boiler systems with matching pressure-control requirements.<\/p>\n<h2 data-section-id=\"17gmcsy\" data-start=\"4308\" data-end=\"4331\">Silter Steam Boilers<\/h2>\n<p data-start=\"4333\" data-end=\"4455\">Suitable for compatible Silter steam boiler and ironing equipment where the existing pressure switch specifications match.<\/p>\n<h2 data-section-id=\"1u7qfpu\" data-start=\"4457\" data-end=\"4492\">3L \/ 5L Commercial Steam Boilers<\/h2>\n<p data-start=\"4494\" data-end=\"4620\">Suitable for compatible <strong data-start=\"4518\" data-end=\"4567\">3L and 5L industrial\/commercial steam boilers<\/strong>, provided the original pressure switch has matching:<\/p>\n<ul data-start=\"4622\" data-end=\"4729\">\n<li data-section-id=\"4ygclu\" data-start=\"4622\" data-end=\"4638\">Pressure range<\/li>\n<li data-section-id=\"1epluhn\" data-start=\"4639\" data-end=\"4661\">Thread specification<\/li>\n<li data-section-id=\"8jy0ip\" data-start=\"4662\" data-end=\"4681\">Electrical rating<\/li>\n<li data-section-id=\"1jm8pre\" data-start=\"4682\" data-end=\"4707\">Switching configuration<\/li>\n<li data-section-id=\"1lbuvpa\" data-start=\"4708\" data-end=\"4729\">Physical dimensions<\/li>\n<\/ul>\n<p data-start=\"4731\" data-end=\"4788\"><strong data-start=\"4731\" data-end=\"4788\">Boiler capacity alone does not confirm compatibility.<\/strong><\/p>\n<h1 data-section-id=\"3ixgg6\" data-start=\"4790\" data-end=\"4812\">THREAD COMPATIBILITY<\/h1>\n<p data-start=\"4814\" data-end=\"4884\">The product is specified with a <strong data-start=\"4846\" data-end=\"4883\">1\/4&#8243; threaded pressure connection<\/strong>.<\/p>\n<p data-start=\"4886\" data-end=\"4936\">Before ordering, confirm whether your boiler uses:<\/p>\n<ul data-start=\"4938\" data-end=\"4990\">\n<li data-section-id=\"385ubl\" data-start=\"4938\" data-end=\"4948\">1\/4&#8243; BSP<\/li>\n<li data-section-id=\"3864fe\" data-start=\"4949\" data-end=\"4959\">1\/4&#8243; NPT<\/li>\n<li data-section-id=\"3skfq6\" data-start=\"4960\" data-end=\"4990\">Another 1\/4&#8243; thread standard<\/li>\n<\/ul>\n<p data-start=\"4992\" data-end=\"5067\"><strong data-start=\"4992\" data-end=\"5067\">1\/4&#8243; BSP and 1\/4&#8243; NPT should not be treated as interchangeable threads.<\/strong><\/p>\n<p data-start=\"5069\" data-end=\"5185\">If the thread type is uncertain, compare the original pressure switch or consult the boiler manufacturer\/technician.<\/p>\n<h1 data-section-id=\"il0wea\" data-start=\"5187\" data-end=\"5208\">COMMON APPLICATIONS<\/h1>\n<p data-start=\"5210\" data-end=\"5262\">The XP110 pressure switch can be used in compatible:<\/p>\n<ul data-start=\"5264\" data-end=\"5560\">\n<li data-section-id=\"1mu843s\" data-start=\"5264\" data-end=\"5288\">Industrial steam irons<\/li>\n<li data-section-id=\"9jsl67\" data-start=\"5289\" data-end=\"5312\">Steam boiler machines<\/li>\n<li data-section-id=\"qtf5y\" data-start=\"5313\" data-end=\"5331\">Steam generators<\/li>\n<li data-section-id=\"1d0fxgf\" data-start=\"5332\" data-end=\"5359\">Garment pressing machines<\/li>\n<li data-section-id=\"13gz5jq\" data-start=\"5360\" data-end=\"5394\">Commercial steam ironing systems<\/li>\n<li data-section-id=\"1qhy1fg\" data-start=\"5395\" data-end=\"5423\">Laundry pressing equipment<\/li>\n<li data-section-id=\"1u5ja20\" data-start=\"5424\" data-end=\"5453\">Textile finishing machinery<\/li>\n<li data-section-id=\"1eam5lc\" data-start=\"5454\" data-end=\"5494\">Industrial garment finishing equipment<\/li>\n<li data-section-id=\"1f63bwg\" data-start=\"5495\" data-end=\"5526\">Boiler heating-control panels<\/li>\n<li data-section-id=\"1hbthhg\" data-start=\"5527\" data-end=\"5560\">Steam generator control systems<\/li>\n<\/ul>\n<h1 data-section-id=\"1hy9ko6\" data-start=\"5562\" data-end=\"5598\">TYPICAL PRESSURE-CONTROL OPERATION<\/h1>\n<h3 data-section-id=\"1io1fk9\" data-start=\"5600\" data-end=\"5635\">Step 1 \u2013 Boiler Pressure Builds<\/h3>\n<p data-start=\"5637\" data-end=\"5706\">The boiler heating element raises the temperature and steam pressure.<\/p>\n<h3 data-section-id=\"zphl3g\" data-start=\"5708\" data-end=\"5741\">Step 2 \u2013 Pressure Is Detected<\/h3>\n<p data-start=\"5743\" data-end=\"5825\">The XP110&#8217;s pressure-sensing mechanism responds to the increasing boiler pressure.<\/p>\n<h3 data-section-id=\"hrimmt\" data-start=\"5827\" data-end=\"5863\">Step 3 \u2013 Set Pressure Is Reached<\/h3>\n<p data-start=\"5865\" data-end=\"5954\">When the configured switching threshold is reached, the electrical contacts change state.<\/p>\n<h3 data-section-id=\"xksywp\" data-start=\"5956\" data-end=\"5992\">Step 4 \u2013 Heating Control Changes<\/h3>\n<p data-start=\"5994\" data-end=\"6072\">The connected control circuit can switch the heating element or contactor OFF.<\/p>\n<h3 data-section-id=\"ic1csj\" data-start=\"6074\" data-end=\"6101\">Step 5 \u2013 Pressure Falls<\/h3>\n<p data-start=\"6103\" data-end=\"6166\">As steam is consumed during ironing, boiler pressure decreases.<\/p>\n<h3 data-section-id=\"1i3aast\" data-start=\"6168\" data-end=\"6197\">Step 6 \u2013 Heating Restarts<\/h3>\n<p data-start=\"6199\" data-end=\"6306\">When the pressure reaches the configured restart threshold, the control circuit can switch heating back ON.<\/p>\n<p data-start=\"6308\" data-end=\"6431\"><strong data-start=\"6308\" data-end=\"6431\">The actual cut-in\/cut-out behaviour depends on the pressure-switch adjustment, differential and boiler control circuit.<\/strong><\/p>\n<h1 data-section-id=\"1tfps89\" data-start=\"6433\" data-end=\"6462\">IMPORTANT: PRESSURE SETTING<\/h1>\n<p data-start=\"6464\" data-end=\"6525\">Pressure adjustment should <strong data-start=\"6491\" data-end=\"6498\">not<\/strong> be performed by guesswork.<\/p>\n<p data-start=\"6527\" data-end=\"6573\">The correct pressure setting must be based on:<\/p>\n<ul data-start=\"6575\" data-end=\"6773\">\n<li data-section-id=\"1hqva4p\" data-start=\"6575\" data-end=\"6612\">Boiler manufacturer&#8217;s specification<\/li>\n<li data-section-id=\"1kjkc01\" data-start=\"6613\" data-end=\"6638\">Safe operating pressure<\/li>\n<li data-section-id=\"oals9l\" data-start=\"6639\" data-end=\"6668\">Heating system requirements<\/li>\n<li data-section-id=\"14w0oa6\" data-start=\"6669\" data-end=\"6693\">Pressure gauge reading<\/li>\n<li data-section-id=\"10rd26f\" data-start=\"6694\" data-end=\"6716\">Safety-valve setting<\/li>\n<li data-section-id=\"1dt0f8t\" data-start=\"6717\" data-end=\"6740\">Pressure-switch range<\/li>\n<li data-section-id=\"1ydcz3v\" data-start=\"6741\" data-end=\"6773\">Machine operating instructions<\/li>\n<\/ul>\n<p data-start=\"6775\" data-end=\"6854\">Do not set the pressure switch above the boiler&#8217;s permitted operating pressure.<\/p>\n<h1 data-section-id=\"191tkzn\" data-start=\"6856\" data-end=\"6880\">PRODUCT SPECIFICATIONS<\/h1>\n<div class=\"group TyagGW_tableContainer\">\n<div class=\"TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\">\n<table class=\"w-fit min-w-(--thread-content-width)\" data-start=\"6882\" data-end=\"7318\">\n<thead data-start=\"6882\" data-end=\"6909\">\n<tr data-start=\"6882\" data-end=\"6909\">\n<th class=\"last:pe-10\" data-start=\"6882\" data-end=\"6898\" data-col-size=\"sm\">\u0935\u093f\u0928\u093f\u0930\u094d\u0926\u0947\u0936<\/th>\n<th class=\"last:pe-10\" data-start=\"6898\" data-end=\"6909\" data-col-size=\"sm\">\u0935\u093f\u0935\u0930\u0923<\/th>\n<\/tr>\n<\/thead>\n<tbody data-start=\"6920\" data-end=\"7318\">\n<tr data-start=\"6920\" data-end=\"6975\">\n<td data-start=\"6920\" data-end=\"6935\" data-col-size=\"sm\">\u0909\u0924\u094d\u092a\u093e\u0926 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/td>\n<td data-start=\"6935\" data-end=\"6975\" data-col-size=\"sm\">Miniature Adjustable Pressure Switch<\/td>\n<\/tr>\n<tr data-start=\"6976\" data-end=\"6993\">\n<td data-start=\"6976\" data-end=\"6984\" data-col-size=\"sm\">\u0928\u092e\u0942\u0928\u093e<\/td>\n<td data-start=\"6984\" data-end=\"6993\" data-col-size=\"sm\">XP110<\/td>\n<\/tr>\n<tr data-start=\"6994\" data-end=\"7035\">\n<td data-start=\"6994\" data-end=\"7008\" data-col-size=\"sm\">\u0906\u0935\u0947\u0926\u0928<\/td>\n<td data-col-size=\"sm\" data-start=\"7008\" data-end=\"7035\">Industrial Steam Boiler<\/td>\n<\/tr>\n<tr data-start=\"7036\" data-end=\"7070\">\n<td data-start=\"7036\" data-end=\"7049\" data-col-size=\"sm\">Connection<\/td>\n<td data-start=\"7049\" data-end=\"7070\" data-col-size=\"sm\">1\/4&#8243; Male Thread*<\/td>\n<\/tr>\n<tr data-start=\"7071\" data-end=\"7111\">\n<td data-start=\"7071\" data-end=\"7089\" data-col-size=\"sm\">Thread Standard<\/td>\n<td data-start=\"7089\" data-end=\"7111\" data-col-size=\"sm\">BSP \/ NPT Variant*<\/td>\n<\/tr>\n<tr data-start=\"7112\" data-end=\"7149\">\n<td data-start=\"7112\" data-end=\"7123\" data-col-size=\"sm\">\u0938\u092e\u093e\u0930\u094b\u0939<\/td>\n<td data-start=\"7123\" data-end=\"7149\" data-col-size=\"sm\">Steam Pressure Control<\/td>\n<\/tr>\n<tr data-start=\"7150\" data-end=\"7193\">\n<td data-start=\"7150\" data-end=\"7167\" data-col-size=\"sm\">Switching Type<\/td>\n<td data-col-size=\"sm\" data-start=\"7167\" data-end=\"7193\">Mechanical Microswitch<\/td>\n<\/tr>\n<tr data-start=\"7194\" data-end=\"7228\">\n<td data-start=\"7194\" data-end=\"7213\" data-col-size=\"sm\">Pressure Setting<\/td>\n<td data-start=\"7213\" data-end=\"7228\" data-col-size=\"sm\">Adjustable*<\/td>\n<\/tr>\n<tr data-start=\"7229\" data-end=\"7268\">\n<td data-start=\"7229\" data-end=\"7244\" data-col-size=\"sm\">Installation<\/td>\n<td data-start=\"7244\" data-end=\"7268\" data-col-size=\"sm\">Boiler Pressure Port<\/td>\n<\/tr>\n<tr data-start=\"7269\" data-end=\"7296\">\n<td data-start=\"7269\" data-end=\"7285\" data-col-size=\"sm\">\u092a\u0948\u0915 \u092e\u093e\u0924\u094d\u0930\u093e<\/td>\n<td data-start=\"7285\" data-end=\"7296\" data-col-size=\"sm\">1 \u091f\u0941\u0915\u0921\u093c\u093e<\/td>\n<\/tr>\n<tr data-start=\"7297\" data-end=\"7318\">\n<td data-start=\"7297\" data-end=\"7311\" data-col-size=\"sm\">\u0915\u092a\u0921\u093c\u0947 \u0915\u093e \u092a\u094d\u0930\u0915\u093e\u0930<\/td>\n<td data-start=\"7311\" data-end=\"7318\" data-col-size=\"sm\">N\/A<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n<\/div>\n<p data-start=\"7320\" data-end=\"7441\"><strong data-start=\"7320\" data-end=\"7441\">*Verify the exact thread standard, pressure range and electrical rating of the supplied variant before installation.<\/strong><\/p>\n<h1 data-section-id=\"e4u90i\" data-start=\"7443\" data-end=\"7484\">WHY REPLACE THE BOILER PRESSURE SWITCH?<\/h1>\n<p data-start=\"7486\" data-end=\"7533\">A faulty or worn pressure switch may result in:<\/p>\n<ul data-start=\"7535\" data-end=\"7757\">\n<li data-section-id=\"1dmndib\" data-start=\"7535\" data-end=\"7575\">Boiler heating not switching correctly<\/li>\n<li data-section-id=\"nih8s6\" data-start=\"7576\" data-end=\"7609\">Heating staying ON continuously<\/li>\n<li data-section-id=\"dntumy\" data-start=\"7610\" data-end=\"7643\">Heating switching OFF too early<\/li>\n<li data-section-id=\"2pn9kl\" data-start=\"7644\" data-end=\"7669\">Unstable steam pressure<\/li>\n<li data-section-id=\"vatcu9\" data-start=\"7670\" data-end=\"7698\">Incorrect pressure cycling<\/li>\n<li data-section-id=\"11d9cy2\" data-start=\"7699\" data-end=\"7733\">Intermittent electrical contacts<\/li>\n<li data-section-id=\"gh4zk9\" data-start=\"7734\" data-end=\"7757\">Boiler control faults<\/li>\n<\/ul>\n<p data-start=\"7759\" data-end=\"7864\">Replacing the pressure switch with a correctly specified unit can restore pressure-based heating control.<\/p>\n<h1 data-section-id=\"1fsfang\" data-start=\"7866\" data-end=\"7891\">COMPATIBILITY CHECKLIST<\/h1>\n<p data-start=\"7893\" data-end=\"7952\">Before ordering, compare your existing pressure switch for:<\/p>\n<ul data-start=\"7954\" data-end=\"8223\">\n<li data-section-id=\"xw07kw\" data-start=\"7954\" data-end=\"7985\"><strong data-start=\"7956\" data-end=\"7985\">XP110 model\/configuration<\/strong><\/li>\n<li data-section-id=\"3ez7pn\" data-start=\"7986\" data-end=\"8004\">1\/4&#8243; thread size<\/li>\n<li data-section-id=\"1qrbcq3\" data-start=\"8005\" data-end=\"8033\">BSP or NPT thread standard<\/li>\n<li data-section-id=\"4ygclu\" data-start=\"8034\" data-end=\"8050\">Pressure range<\/li>\n<li data-section-id=\"5evecl\" data-start=\"8051\" data-end=\"8068\">Cut-in pressure<\/li>\n<li data-section-id=\"wti0gc\" data-start=\"8069\" data-end=\"8087\">Cut-out pressure<\/li>\n<li data-section-id=\"k3m6g1\" data-start=\"8088\" data-end=\"8115\">Electrical contact rating<\/li>\n<li data-section-id=\"3j5pzv\" data-start=\"8116\" data-end=\"8148\">Number of electrical terminals<\/li>\n<li data-section-id=\"c8qor7\" data-start=\"8149\" data-end=\"8171\">Mounting orientation<\/li>\n<li data-section-id=\"1lbuvpa\" data-start=\"8172\" data-end=\"8193\">Physical dimensions<\/li>\n<li data-section-id=\"sobpyh\" data-start=\"8194\" data-end=\"8223\">Pressure-port configuration<\/li>\n<\/ul>\n<p data-start=\"8225\" data-end=\"8351\"><strong data-start=\"8225\" data-end=\"8351\">Do not purchase based on model name alone. Matching the pressure range, thread and electrical specifications is essential.<\/strong><\/p>\n<h1 data-section-id=\"so7ku2\" data-start=\"8353\" data-end=\"8367\">INSTALLATION<\/h1>\n<p data-start=\"8369\" data-end=\"8552\">The XP110 is used in <strong data-start=\"8390\" data-end=\"8458\">pressurized steam boiler systems and electrical heating circuits<\/strong>. Installation and adjustment should be performed by a qualified boiler\/electrical technician.<\/p>\n<p data-start=\"8554\" data-end=\"8584\">General replacement procedure:<\/p>\n<ol data-start=\"8586\" data-end=\"9329\">\n<li data-section-id=\"7qj206\" data-start=\"8586\" data-end=\"8631\">Switch OFF the boiler&#8217;s electrical supply.<\/li>\n<li data-section-id=\"1exqqlc\" data-start=\"8632\" data-end=\"8671\">Allow the boiler to cool completely.<\/li>\n<li data-section-id=\"1gzufqp\" data-start=\"8672\" data-end=\"8741\">Release pressure according to the boiler manufacturer&#8217;s procedure.<\/li>\n<li data-section-id=\"1wfmd67\" data-start=\"8742\" data-end=\"8792\">Confirm that the boiler is fully depressurized.<\/li>\n<li data-section-id=\"1sa0msh\" data-start=\"8793\" data-end=\"8843\">Disconnect the existing pressure switch wiring.<\/li>\n<li data-section-id=\"10isk9r\" data-start=\"8844\" data-end=\"8888\">Record the original terminal connections.<\/li>\n<li data-section-id=\"1sl7z61\" data-start=\"8889\" data-end=\"8928\">Remove the existing pressure switch.<\/li>\n<li data-section-id=\"6s2zp5\" data-start=\"8929\" data-end=\"8986\">Verify the replacement thread matches the boiler port.<\/li>\n<li data-section-id=\"et9uq8\" data-start=\"8987\" data-end=\"9055\">Install the XP110 using an appropriate compatible sealing method.<\/li>\n<li data-section-id=\"1vf2fji\" data-start=\"9056\" data-end=\"9131\">Connect the electrical wiring according to the original boiler circuit.<\/li>\n<li data-section-id=\"1aqak24\" data-start=\"9132\" data-end=\"9166\">Check for steam\/water leakage.<\/li>\n<li data-section-id=\"1v435j4\" data-start=\"9167\" data-end=\"9216\">Verify the pressure gauge and safety devices.<\/li>\n<li data-section-id=\"1ykp8tj\" data-start=\"9217\" data-end=\"9275\">Test the pressure-switch operation at a safe pressure.<\/li>\n<li data-section-id=\"1qs7kn\" data-start=\"9276\" data-end=\"9329\">Confirm that the heating system cycles correctly.<\/li>\n<\/ol>\n<p data-start=\"9331\" data-end=\"9377\"><strong data-start=\"9331\" data-end=\"9377\">Never work on a hot or pressurized boiler.<\/strong><\/p>\n<h1 data-section-id=\"ihnzfa\" data-start=\"9379\" data-end=\"9399\">SAFETY INFORMATION<\/h1>\n<p data-start=\"9401\" data-end=\"9511\">This product is used with <strong data-start=\"9427\" data-end=\"9510\">pressurized steam, high temperatures and potentially hazardous electrical loads<\/strong>.<\/p>\n<p data-start=\"9513\" data-end=\"9532\">For safe operation:<\/p>\n<ul data-start=\"9534\" data-end=\"10152\">\n<li data-section-id=\"17rxhrr\" data-start=\"9534\" data-end=\"9603\">Never open or remove the pressure switch from a pressurized boiler.<\/li>\n<li data-section-id=\"1rqztbg\" data-start=\"9604\" data-end=\"9648\">Allow the boiler to cool before servicing.<\/li>\n<li data-section-id=\"2ybddj\" data-start=\"9649\" data-end=\"9697\">Disconnect mains power before electrical work.<\/li>\n<li data-section-id=\"1jk8mx4\" data-start=\"9698\" data-end=\"9733\">Never bypass the pressure switch.<\/li>\n<li data-section-id=\"4o5ddg\" data-start=\"9734\" data-end=\"9773\">Never bypass the boiler safety valve.<\/li>\n<li data-section-id=\"nreot6\" data-start=\"9774\" data-end=\"9835\">Never operate without the required pressure-relief devices.<\/li>\n<li data-section-id=\"163ni0i\" data-start=\"9836\" data-end=\"9888\">Do not exceed the boiler&#8217;s rated working pressure.<\/li>\n<li data-section-id=\"hpu24z\" data-start=\"9889\" data-end=\"9955\">Do not exceed the pressure switch&#8217;s specified electrical rating.<\/li>\n<li data-section-id=\"3t34mi\" data-start=\"9956\" data-end=\"10033\">Use a suitable relay\/contactor for high-power heating loads where required.<\/li>\n<li data-section-id=\"1o52hsj\" data-start=\"10034\" data-end=\"10090\">Verify the pressure gauge before adjusting the switch.<\/li>\n<li data-section-id=\"1658mnc\" data-start=\"10091\" data-end=\"10152\">Installation should be performed by a qualified technician.<\/li>\n<\/ul>\n<h1 data-section-id=\"hf4mak\" data-start=\"10154\" data-end=\"10182\">FREQUENTLY ASKED QUESTIONS<\/h1>\n<h3 data-section-id=\"12rpkmh\" data-start=\"10184\" data-end=\"10221\">What is an XP110 pressure switch?<\/h3>\n<p data-start=\"10223\" data-end=\"10417\">The <strong data-start=\"10227\" data-end=\"10236\">XP110<\/strong> is a miniature adjustable mechanical pressure switch used to monitor pressure and control an electrical circuit in compatible steam boilers and other pressure-control applications.<\/p>\n<h3 data-section-id=\"1xqu3l0\" data-start=\"10419\" data-end=\"10464\">What is the main function of this switch?<\/h3>\n<p data-start=\"10466\" data-end=\"10563\">Its primary function is to switch an electrical circuit according to a preset pressure condition.<\/p>\n<h3 data-section-id=\"97yj6f\" data-start=\"10565\" data-end=\"10609\">Can it control a boiler heating element?<\/h3>\n<p data-start=\"10611\" data-end=\"10764\">Yes, when correctly selected and installed in a compatible boiler control circuit. For high-power heating elements, a contactor or relay may be required.<\/p>\n<h3 data-section-id=\"15uio6a\" data-start=\"10766\" data-end=\"10801\">What thread does the XP110 use?<\/h3>\n<p data-start=\"10803\" data-end=\"10938\">This product is specified with a <strong data-start=\"10836\" data-end=\"10869\">1\/4&#8243; male threaded connection<\/strong>. Verify whether your required version is BSP or NPT before ordering.<\/p>\n<h3 data-section-id=\"1v14o6k\" data-start=\"10940\" data-end=\"10979\">Are 1\/4&#8243; BSP and 1\/4&#8243; NPT the same?<\/h3>\n<p data-start=\"10981\" data-end=\"11066\">No. They are different thread standards and should not be treated as interchangeable.<\/p>\n<h3 data-section-id=\"v7vyfg\" data-start=\"11068\" data-end=\"11106\">Can I use it on a 3L steam boiler?<\/h3>\n<p data-start=\"11108\" data-end=\"11232\">It can be used on a compatible 3L boiler if the pressure range, thread, electrical rating and switching configuration match.<\/p>\n<h3 data-section-id=\"1nrb1nk\" data-start=\"11234\" data-end=\"11274\">Can it be used on a 5L steam boiler?<\/h3>\n<p data-start=\"11276\" data-end=\"11374\">Yes, it can be suitable for a compatible 5L industrial steam boiler when all specifications match.<\/p>\n<h3 data-section-id=\"17u8wcj\" data-start=\"11376\" data-end=\"11424\">Is it compatible with Magneto steam boilers?<\/h3>\n<p data-start=\"11426\" data-end=\"11552\">It can be used with compatible <strong data-start=\"11457\" data-end=\"11468\">\u092c\u093f\u091c\u0932\u0940 \u0915\u0940 \u0936\u0915\u094d\u0924\u093f \u0909\u0924\u094d\u092a\u0928\u094d\u0928 \u0915\u0930\u0928\u0947 \u0915\u093e \u092f\u0902\u0924\u094d\u0930<\/strong> boiler systems where the original pressure switch matches the XP110 specifications.<\/p>\n<h3 data-section-id=\"1mtsrfx\" data-start=\"11554\" data-end=\"11590\">Does it fit Silver Star boilers?<\/h3>\n<p data-start=\"11592\" data-end=\"11714\">It is suitable for compatible <strong data-start=\"11622\" data-end=\"11637\">Silver Star<\/strong> systems when the pressure range, thread and electrical specifications match.<\/p>\n<h3 data-section-id=\"7ex2a9\" data-start=\"11716\" data-end=\"11756\">Can it be used with Hashima boilers?<\/h3>\n<p data-start=\"11758\" data-end=\"11859\">Yes, it can be suitable for compatible <strong data-start=\"11797\" data-end=\"11808\">Hashima<\/strong> steam boiler systems with matching specifications.<\/p>\n<h3 data-section-id=\"1h384d4\" data-start=\"11861\" data-end=\"11900\">Is it compatible with Veit boilers?<\/h3>\n<p data-start=\"11902\" data-end=\"12012\">It can be used in compatible <strong data-start=\"11931\" data-end=\"11939\">Veit<\/strong> steam equipment where the original pressure switch specifications match.<\/p>\n<h3 data-section-id=\"1v3hiov\" data-start=\"12014\" data-end=\"12054\">Can it be used with Naomoto boilers?<\/h3>\n<p data-start=\"12056\" data-end=\"12169\">Yes, it can be suitable for compatible <strong data-start=\"12095\" data-end=\"12106\">Naomoto<\/strong> industrial steam boiler systems when the specifications match.<\/p>\n<h3 data-section-id=\"1bkknjh\" data-start=\"12171\" data-end=\"12209\">Is it suitable for Silter boilers?<\/h3>\n<p data-start=\"12211\" data-end=\"12319\">It can be used with compatible <strong data-start=\"12242\" data-end=\"12252\">Silter<\/strong> steam boiler systems with matching pressure-switch specifications.<\/p>\n<h3 data-section-id=\"190vcp4\" data-start=\"12321\" data-end=\"12352\">Is the pressure adjustable?<\/h3>\n<p data-start=\"12354\" data-end=\"12525\">Yes. The XP110 design includes an adjustable pressure-setting mechanism. The setting must be adjusted according to the boiler manufacturer&#8217;s safe operating specifications.<\/p>\n<h3 data-section-id=\"t781x0\" data-start=\"12527\" data-end=\"12588\">Does the pressure switch replace the boiler safety valve?<\/h3>\n<p data-start=\"12590\" data-end=\"12714\"><strong data-start=\"12590\" data-end=\"12597\">\u0928\u0939\u0940\u0902\u0964.<\/strong> A pressure switch is a control device and should not be treated as a replacement for a safety\/pressure-relief valve.<\/p>\n<h3 data-section-id=\"195zdh\" data-start=\"12716\" data-end=\"12753\">Can I adjust the pressure myself?<\/h3>\n<p data-start=\"12755\" data-end=\"12889\">Pressure adjustment should be performed by a qualified technician using the boiler&#8217;s pressure gauge and manufacturer&#8217;s specifications.<\/p>\n<h3 data-section-id=\"16exgul\" data-start=\"12891\" data-end=\"12942\">How do I know if this pressure switch will fit?<\/h3>\n<p data-start=\"12944\" data-end=\"12952\">\u0924\u0941\u0932\u0928\u093e \u0915\u0930\u0928\u093e:<\/p>\n<ul data-start=\"12954\" data-end=\"13101\">\n<li data-section-id=\"1wwol0j\" data-start=\"12954\" data-end=\"12967\">Thread size<\/li>\n<li data-section-id=\"1e9gzuf\" data-start=\"12968\" data-end=\"12986\">BSP\/NPT standard<\/li>\n<li data-section-id=\"4ygclu\" data-start=\"12987\" data-end=\"13003\">Pressure range<\/li>\n<li data-section-id=\"8jy0ip\" data-start=\"13004\" data-end=\"13023\">Electrical rating<\/li>\n<li data-section-id=\"sdu3zw\" data-start=\"13024\" data-end=\"13048\">Terminal configuration<\/li>\n<li data-section-id=\"1lbuvpa\" data-start=\"13049\" data-end=\"13070\">Physical dimensions<\/li>\n<li data-section-id=\"i060zl\" data-start=\"13071\" data-end=\"13101\">Original model\/configuration<\/li>\n<\/ul>","protected":false},"excerpt":{"rendered":"<p>XP110 miniature adjustable pressure switch with 1\/4&#8243; threaded connection for compatible industrial steam iron boilers and steam generators. Designed for pressure-based heating control in compatible systems.<\/p>","protected":false},"featured_media":20755,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_yoast_wpseo_focuskw":"XP110 pressure switch","_yoast_wpseo_title":"XP110 1\/4\" Adjustable Pressure Switch for Boiler Steam Iron %%sep%% %%sitename%%","_yoast_wpseo_metadesc":"XP110 1\/4\" adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.","_yoast_wpseo_meta-robots-noindex":"","_yoast_wpseo_meta-robots-nofollow":"","_yoast_wpseo_bctitle":"","_yoast_wpseo_canonical":"","_yoast_wpseo_opengraph-title":"","_yoast_wpseo_opengraph-description":"","_yoast_wpseo_twitter-title":"","_yoast_wpseo_twitter-description":"","_angie_page":false},"product_brand":[],"product_cat":[949,950],"product_tag":[3005,3006,3004,3007,3010,3013,3008,3011,3015,3016,3012,3009,3003,3014,3002,3001],"class_list":["post-20749","product","type-product","status-publish","has-post-thumbnail","product_cat-industrial-steam-iron-and-parts","product_cat-vacuum-table-and-boiler-parts","product_tag-1-4-bsp-pressure-switch","product_tag-1-4-npt-pressure-switch","product_tag-1-4-pressure-switch","product_tag-adjustable-steam-pressure-switch","product_tag-boiler-heating-control-switch","product_tag-hashima-pressure-switch","product_tag-industrial-boiler-pressure-switch","product_tag-magneto-pressure-switch","product_tag-naomoto-pressure-switch","product_tag-silter-pressure-switch","product_tag-silver-star-pressure-switch","product_tag-steam-generator-pressure-controller","product_tag-steam-iron-pressure-switch","product_tag-veit-pressure-switch","product_tag-xp110-boiler-pressure-switch","product_tag-xp110-pressure-switch","first","instock","sale","shipping-taxable","purchasable","product-type-simple"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>XP110 1\/4&quot; Adjustable Pressure Switch for Boiler Steam Iron - Stitch Partner<\/title>\n<meta name=\"description\" content=\"XP110 1\/4&quot; adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/stitchpartner.com\/hi\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/\" \/>\n<meta property=\"og:locale\" content=\"hi_IN\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"XP110 1\/4&quot; Adjustable Pressure Switch for Boiler Steam Iron - Stitch Partner\" \/>\n<meta property=\"og:description\" content=\"XP110 1\/4&quot; adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/stitchpartner.com\/hi\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/\" \/>\n<meta property=\"og:site_name\" content=\"Stitch Partner\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/467613100111433\" \/>\n<meta property=\"article:modified_time\" content=\"2026-08-29T17:26:36+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/stitchpartner.com\/wp-content\/uploads\/2026\/08\/1-4-inch-miniature-boiler-heating-pressure-switch-xp110.jpg.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1040\" \/>\n\t<meta property=\"og:image:height\" content=\"1040\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u0905\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u092a\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u092e\u092f\" \/>\n\t<meta name=\"twitter:data1\" content=\"8 \u092e\u093f\u0928\u091f\" \/>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"XP110 1\/4\" Adjustable Pressure Switch for Boiler Steam Iron - Stitch Partner","description":"XP110 1\/4\" adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/stitchpartner.com\/hi\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/","og_locale":"hi_IN","og_type":"article","og_title":"XP110 1\/4\" Adjustable Pressure Switch for Boiler Steam Iron - Stitch Partner","og_description":"XP110 1\/4\" adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.","og_url":"https:\/\/stitchpartner.com\/hi\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/","og_site_name":"Stitch Partner","article_publisher":"https:\/\/www.facebook.com\/467613100111433","article_modified_time":"2026-08-29T17:26:36+00:00","og_image":[{"width":1040,"height":1040,"url":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2026\/08\/1-4-inch-miniature-boiler-heating-pressure-switch-xp110.jpg.jpg","type":"image\/jpeg"}],"twitter_card":"summary_large_image","twitter_misc":{"\u0905\u0928\u0941\u092e\u093e\u0928\u093f\u0924 \u092a\u0922\u093c\u0928\u0947 \u0915\u093e \u0938\u092e\u092f":"8 \u092e\u093f\u0928\u091f"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/","url":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/","name":"XP110 1\/4\" Adjustable Pressure Switch for Boiler Steam Iron - Stitch Partner","isPartOf":{"@id":"https:\/\/stitchpartner.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/#primaryimage"},"image":{"@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/#primaryimage"},"thumbnailUrl":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2026\/08\/1-4-inch-miniature-boiler-heating-pressure-switch-xp110.jpg.jpg","datePublished":"2026-08-25T12:40:39+00:00","dateModified":"2026-08-29T17:26:36+00:00","description":"XP110 1\/4\" adjustable pressure switch for compatible industrial steam iron boilers, steam generators and 3L\/5L commercial boilers.","breadcrumb":{"@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/#breadcrumb"},"inLanguage":"hi-IN","potentialAction":[{"@type":"ReadAction","target":["https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/"]}]},{"@type":"ImageObject","inLanguage":"hi-IN","@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/#primaryimage","url":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2026\/08\/1-4-inch-miniature-boiler-heating-pressure-switch-xp110.jpg.jpg","contentUrl":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2026\/08\/1-4-inch-miniature-boiler-heating-pressure-switch-xp110.jpg.jpg","width":1040,"height":1040,"caption":"Steam generator pressure switch for 3L 5L industrial boiler"},{"@type":"BreadcrumbList","@id":"https:\/\/stitchpartner.com\/product\/xp110-1-4-adjustable-pressure-switch-boiler-steam-iron\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/stitchpartner.com\/"},{"@type":"ListItem","position":2,"name":"Shop","item":"https:\/\/stitchpartner.com\/shop\/"},{"@type":"ListItem","position":3,"name":"XP110 1\/4&#8243; Adjustable Pressure Switch for Boiler Steam Iron"}]},{"@type":"WebSite","@id":"https:\/\/stitchpartner.com\/#website","url":"https:\/\/stitchpartner.com\/","name":"\u0938\u094d\u091f\u093f\u091a \u092a\u093e\u0930\u094d\u091f\u0928\u0930","description":"JACK SEWING MACHINE SPARE PARTS","publisher":{"@id":"https:\/\/stitchpartner.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/stitchpartner.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"hi-IN"},{"@type":"Organization","@id":"https:\/\/stitchpartner.com\/#organization","name":"\u0938\u094d\u091f\u093f\u091a \u092a\u093e\u0930\u094d\u091f\u0928\u0930","url":"https:\/\/stitchpartner.com\/","logo":{"@type":"ImageObject","inLanguage":"hi-IN","@id":"https:\/\/stitchpartner.com\/#\/schema\/logo\/image\/","url":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2025\/01\/stitchpartnerfinal-pg3-1000-x-285-px.svg","contentUrl":"https:\/\/stitchpartner.com\/wp-content\/uploads\/2025\/01\/stitchpartnerfinal-pg3-1000-x-285-px.svg","width":750,"height":213,"caption":"Stitch Partner"},"image":{"@id":"https:\/\/stitchpartner.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/467613100111433","https:\/\/youtube.com\/@stitch.partner","https:\/\/whatsapp.com\/channel\/0029Vb8jjZQDOQIeiYI6gB1k"]}]}},"_links":{"self":[{"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product\/20749","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/comments?post=20749"}],"version-history":[{"count":3,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product\/20749\/revisions"}],"predecessor-version":[{"id":21086,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product\/20749\/revisions\/21086"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/media\/20755"}],"wp:attachment":[{"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/media?parent=20749"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product_brand?post=20749"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product_cat?post=20749"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/stitchpartner.com\/hi\/wp-json\/wp\/v2\/product_tag?post=20749"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}